Genetic Engineering Research - Product

Product Quick Search

Code

Name

DetailSearch

One Step PrimeScript™ RT-PCR Kit (Perfect Real Time)

Cat.# Product Size Note
RR064A One Step PrimeScript™ RT-PCR Kit (Perfect Real Time) License 100 reactions
RR064B(A×5) One Step PrimeScript™ RT-PCR Kit (Perfect Real Time) License 500 reactions

Description

One Step PrimeScript™ RT-PCR Kit (Perfect Real Time) is designed for real time one-step RT-PCR using TaqMan® probe*1,*2 for detection. In this kit, RT-PCR can be performed all in a single tube subsequently, therefore the operation is simple, and it minimizes the risk of contamination. Also, amplified products are monitored in real time, so there is no need to verify them through electrophoresis after PCR. This kit is suitable for detection of tiny amount of RNA like RNA virus.
This kit uses PrimeScript™ RTase, which has excellent extendibility and can efficiently synthesize cDNA in short time period, and TaKaRa Ex Taq™ HS, high efficiency hot start PCR enzyme, and they are optimized for one step RT-PCR.

Applicable real time PCR instruments

  • Thermal Cycler Dice™ Real Time System (TaKaRa Cat.#TP800)
  • ABI PRISM® 7000/7700/7900HT, 7300/7500 Real-Time PCR System (Applied Biosystems)
  • LightCycler® (Roche Diagnostics)
  • Smart Cycler® System*3/Smart Cycler® II System*3 (Cepheid), and other
*1 TaqMan® is a registered trademark of Roche Molecular Systems Inc.
*2 Use One Step SYBR® PrimeScript™ RT-PCR Kit (Perfect Real Time) for real time one-step RT-PCR using SYBR® Green I for detection.
*3 Smart Cycler® is a registerd trademark of Cepheid.



This product is not available in the U.S.

Storage

-20°C

Kit Contents (for 100 reactions; 50 µl reaction system)

1. 2× One Step RT-PCR Buffer III*1840 µl × 3
2. TaKaRa Ex Taq™ HS (5U / µl)100 µl
3.PrimeScript™ RT enzyme Mix II100 µl
4. RNase Free dH2O1.25 ml × 2
5. ROX Reference Dye (50×conc.)*2100 µl
6. ROX Reference Dye II (50×conc.)*2100 µl

*1 Includes dNTP Mixture and Mg2+.
*2 ROX™ Reference Dye/Dye II is used for normalization of intensity by background subtraction. For ABI PRISM® 7000/7700/7900HT and Applied Biosystems 7300 Real-Time PCR System, the use of ROX™ Reference Dye (50×) is recommended. For Applied Biosystems 7500 Real-Time PCR System, the use of ROX™ Reference Dye II is recommended. The use of ROX™ Reference Dye or Dye II is optional. It is not required for use with Thermal Cycler Dice® Real Time System, Smart Cycler® or LightCycler® real time instruments.

Reagents and Instruments required but not included in the kit
  1. Thermal Cycler for real time PCR
  2. Reaction tube or plate for real time PCR
  3. PCR primers
  4. TaqMan® probe for detection (licensed probes)
  5. dH2O
  6. Micropippets and Micropippet tips (autoclaved prior to use)

Note
  • All products are intended to be used for research purpose only. They are not to be used for drug or diagnostic purposes, nor are they intended for human use. They shall not to be used products as food, cosmetics, or utensils, etc
  • Takara products may not be resold or transferred, modified for resale or transfer, or used to manufacture commercial products without written approval from TAKARA BIO INC.
  • If you require licenses for other use, please call at +81 77 543 7247 or contact from our website at www.takara-bio.com
  • Please confirm the content about the license or patent used in this document that relates to the Takara Bio product by clicking the license mark.
    Moreover, please confirm the "Limited Use Label License" or "patent" concerning the product of another manufacturers or respective owners in their Web site/catalog etc.

Page TOP